Read e-book online ABB handbook protection and control devices PDF

By ABB SACE

Show description

Read or Download ABB handbook protection and control devices PDF

Best nonfiction_3 books

Read e-book online I'm on LinkedIn--Now What??? (First Edition): A Guide to PDF

"I'm on LinkedIn--Now What? ?? (Second Edition)" is a publication designed that will help you get the main out this renowned company networking web site. This new version follows the best-selling first variation and comprises the newest and nice techniques for utilizing LinkedIn. With over 32 million contributors there's a lot of strength to discover and increase relationships to aid on your company and private existence, yet many execs locate themselves puzzling over what to do when they signup.

Get Atlas of Liver Pathology, Second Edition (ATLAS OF SURGICAL PDF

"Beautifully edited and assuredly produced. .. a entire and perfect advisor. "-NEJM, evaluate of the 1st version. Readers will locate authoritative, in-depth visible insurance of the microscopic and macroscopic visual appeal of the entire diversity of hepatic issues, either neoplastic and non-neoplastic. This second version displays the most recent international well-being association type of liver and biliary tract illnesses, and gives 60% extra photos.

Download PDF by D.A. Timashev: Homogeneous Spaces and Equivariant Embeddings

Homogeneous areas of linear algebraic teams lie on the crossroads of algebraic geometry, thought of algebraic teams, classical projective and enumerative geometry, harmonic research, and illustration thought. by means of ordinary purposes of algebraic geometry, with a purpose to resolve a number of difficulties on a homogeneous house, it truly is typical and necessary to compactify it whereas keeping an eye on the crowd motion, i.

Extra resources for ABB handbook protection and control devices

Sample text

For fault current values higher than 1600 A, the circuit-breaker trips instantaneously through magnetic protection. Introduction The following figures show the curves of the single protection functions available in the electronic releases. The setting ranges and resolution are referred to setting operations to be carried out locally. 2 x I1 A= 3s; B= 6s; C= 12s; D= 18s (@ 6 x I1) A= 3s; B= 6s; C= 12s; D= 18s (@ 6 x I1) for T4 In = 320 A and T5 In = 630 A → t1 = 12s. 5 – 2 – 4 – 6 – 8 – 10 – 12 – OFF) x In Here below the tolerances: I2 ± 10 % (T4-T5) PR221 ± 10 % (up to 2 x In) ± 20 % (over 2 x In) PR222 ± 10 % PR211 ± 10 % PR212 101 1 I3 ± 10 % (T4-T5) ± 20 % (T2) ± 10 % for T4 In = 320 A and T5 In = 630 A →I3 max = 10 x In Here below the tolerances: Tripping time: ≤ 25 ms ≤ 25 ms ± 20 % ≤ 25 ms PR111 ± 20 % 35 ms up to 3 x In 30 ms over 3 x In PR112 PR113 ± 10 % up to 4 x In ± 15 % over 4 x In ≤ 25 ms The given tolerances are valid only if the release is self-supplied in steady state condition with two-phase or three-phase power supply.

2 Trip curves 3 General characteristics 3 General characteristics Trip curve electronic releases PR113/P release – Other protection functions The following curves refer to the particular protection functions provided for PR113/P. 3 Limitation curves A circuit-breaker in which the opening of the contacts occurs after the passage of the peak of the short-circuit current, or in which the trip occurs with the natural passage to zero, allows the system components to be subjected to high stresses, of both thermal and dynamic type.

For fault current values higher than 1600 A, the circuit-breaker trips instantaneously through magnetic protection. Introduction The following figures show the curves of the single protection functions available in the electronic releases. The setting ranges and resolution are referred to setting operations to be carried out locally. 2 x I1 A= 3s; B= 6s; C= 12s; D= 18s (@ 6 x I1) A= 3s; B= 6s; C= 12s; D= 18s (@ 6 x I1) for T4 In = 320 A and T5 In = 630 A → t1 = 12s. 5 – 2 – 4 – 6 – 8 – 10 – 12 – OFF) x In Here below the tolerances: I2 ± 10 % (T4-T5) PR221 ± 10 % (up to 2 x In) ± 20 % (over 2 x In) PR222 ± 10 % PR211 ± 10 % PR212 101 1 I3 ± 10 % (T4-T5) ± 20 % (T2) ± 10 % for T4 In = 320 A and T5 In = 630 A →I3 max = 10 x In Here below the tolerances: Tripping time: ≤ 25 ms ≤ 25 ms ± 20 % ≤ 25 ms PR111 ± 20 % 35 ms up to 3 x In 30 ms over 3 x In PR112 PR113 ± 10 % up to 4 x In ± 15 % over 4 x In ≤ 25 ms The given tolerances are valid only if the release is self-supplied in steady state condition with two-phase or three-phase power supply.